Battery Input Data  | 
|---|
Battery type  | Lead-acid or lithium-ion  | 
Battery voltage range (V)  | 200~700  | 
Max. charging current (A)  | 37+37  | 
Max. discharging current (A)  | 37+37  | 
Number of battery inputs  | 2  | 
Charging curve  | 3-stage / equalization  | 
Lithium-ion battery charging  | Auto-adaptation to BMS system  | 
PV String Input Data  | 
|---|
Max. DC input power (W)  | 39000  | 
Max. DC input voltage (V)  | 1000  | 
Start-up voltage (V)  | 160  | 
MPPT voltage range (V)  | 200–850  | 
Nominal DC input voltage (V)  | 150  | 
DC voltage range at full load (V)  | 435–850  | 
Nominal DC input voltage (V)  | 500  | 
PV input current (A)  | 36+36+36  | 
Max. PV ISC (A)  | 50+50+50  | 
Number of MPPT / Strings per MPPT  |  | 
AC Output Data  | 
|---|
Rated AC output and UPS power (W)  | 30000  | 
Max. AC output power (W)  | 33000  | 
Rated AC output current (A)  | 45.6  | 
Max. AC current (A)  | 50.1  | 
Max. continuous AC current (A)  | 100  | 
Peak power (off-grid)  | 2 × rated power, 10 s  | 
Generator input / Smart charging / AC coupling current (A)  | 45.6 / *180 / 45.6  | 
Power factor  | 0.8 leading to 0.8 lagging  | 
Output frequency and voltage  | 50/60Hz; 3L/N/PE 220/380, 230/400Vac  | 
Grid type  | Three-phase  | 
DC current injection (mA)  | <0.5%1n  | 
Efficiency  | 
|---|
Max. efficiency  | 97.60%  | 
Euro efficiency  | 97.00%  | 
MPPT efficiency  | 99.90%  | 
Protection  | 
|---|
Integration  | PV input lightning protection, anti-islanding protection, reverse polarity protection on PV input, insulation resistance detection, residual current monitoring unit, output overcurrent protection, output short-circuit protection, surge protection  | 
Output overvoltage protection  | DC Type II / AC Type III  | 
Certificates & Standards  | 
|---|
Grid regulation  | CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11  | 
EMC Safety / Standard  | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2  | 
General Data  | 
|---|
Operating temperature range (°C)  | -45~60℃, >45℃ derating  | 
Cooling  | Smart cooling  | 
Noise (dB)  | < 45 dB  | 
BMS communication  | RS485; CAN  | 
Weight (kg)  | 60  | 
Dimensions (mm)  | 560.5 W × 837 H × 319 D  | 
Degree of protection  | IP65  | 
Installation style  | Wall-mounted  | 
Warranty  | 5 years  |